Posted by Curt Cooke on January 20, 1999 at 05:38:30:
In Reply to: 1947farmall superA touch control hydraulic series A posted by dspace on January 19, 1999 at 17:02:52:
I agree with Stan, remove the pump and replace the seal on the pump drive shaft. This should cure the fluid escape problem. Once you accomplish this, and without any load on the hydraulics, the rockshafts should move. Be sure to follow the "removing air from the system" procedures when refilling the system. Then you can move on to other tests.