Re: Re: Re: Convert to Alternator- 504 International
[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk ]
Posted by HWooden on November 17, 1998 at 16:59:50:
In Reply to: Re: Re: Convert to Alternator- 504 International posted by D. Molden on November 17, 1998 at 09:57:32:
: : : : : : Can someone tell me what the correct procedure to putting on a Delco single post self : : : igniting alterntor on 504 International tractor that previously had a generator and voltage regulator. It also has a alternator light on the dash. : : Mr molden, : : If its a single wire type and thats what it sounds : : like tape the old wires to gen. so they dont ground to tractor then run a good heavy wire(12ga) : : from battery post on starter to post on alt. i dont think the gen. lite will work with alt. you may want to put a amp ga on. to do that cut the wire you ran from starter to alt then put the end from starter to the - side of ga. and the other wire end to + side of ga. start the motor and go to work. : Thanks a lot randy! A volt meter will work better than an ammeter. IMOP
Follow Ups:
Post a Followup
|