Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver
 
Marketplace
Classified Ads
Photo Ads
Tractor Parts
Salvage

Community
Discussion Forums
Project Journals
Your Stories
Events Calendar
Hauling Schedule

Galleries
Tractor Photos
Implement Photos
Vintage Photos
Help Identify
Parts & Pieces
Stuck & Troubled
Vintage Ads
Community Album
Photo Ad Archives

Research & Info
Articles
Tractor Registry
Tip of the Day
Safety Cartoons
Tractor Values
Serial Numbers
Tune-Up Guide
Paint Codes
List Prices
Production Nbrs
Tune-Up Specs
Torque Values
3-Point Specs
Glossary

Miscellaneous
Tractor Games
Just For Kids
Virtual Show
Museum Guide
Memorial Page
Feedback Form

Yesterday's Tractors Facebook Page

  
Farmall & IHC Tractors Discussion Board

Re: 6 to 12V conversion


[ Expand ] [ View Replies ] [ Add a Reply ] [ Return to Forum ]

Posted by John T on June 24, 2014 at 06:50:10 from (216.249.72.121):

In Reply to: 6 to 12V conversion posted by henryv11 on June 24, 2014 at 05:49:03:

Questions Questions, lets take them one at a time:


Questions:

1. Does the new alternator single terminal get all the wires in the diagram that lead to the generator cutout? That is the YB back to the ammeter; the YR to the main light switch BATT; and the Y to the 12v horn?

The main big single wire output lug could/would feed YES basically all (12 Volts) that was wired to the BAT side of an old Cutout Relay. That would be the LOAD (NOT Battery/Starter) side of the Ammeter,,,,,12 VDC to light switches BAT INPUT etc. Sometimes those loads are fed off the LOAD side of the ammeter but that's electrically the same as BAT on a Cutout Relay or the LOAD side of an ammeter. That's where the BAT on the cutout wires anyway but now the alternators main big output stud.


"If so, does the alternator charge the battery through the circuit running back to the ammeter and to the + side of the battery?"

The alternators charge gets to the battery to charge it VIA THE AMMETER. The LOAD side wires to the alternators output while the SUPPLY side gets to the batterys ungrounded post often where the big battery cable attaches to a starter switch or starter solenoids input. It needs wired at right polarity or would read bass ackwards.

2. My 20 amp ammeter has the pass-through type of connector, not separate terminals, but my wiring harness has terminal connectors. I assume most/all new ammeters will have terminals? Is a 30 amp ammeter enough? I have a Nu-Rex 12v neg ground alternator, but it's been years since I bought it and don't remember the specs. Probably 60 amp max output or something.

A typical new ammeter will have + and - terminals
which I call the LOAD (output and BAT on Cutout or new alternators output) and SUPPLY (input from battery) Sure ideally a 50 or 60 amp ammeter might be used but a 30 will suffice. It may peg for a short period after start up depending on battery condition. Trouble with a 60 is after start up the needle may not move much. A 20 amp may be a bit too small to handle an initial 50 or 60 amp surge but Ive used plenty of 30 amp meters on a 60 amp alternator never had a problem if you don't mind the needle possibly pegging after start up.


Anyone willing to jump in? Also, please...let's not hijack this as to why I should stay on 6v +grnd. :-)

If you insist lol your tractor your choice NOT any of ours

John T


Replies:




Add a Reply

:
:
:

:

:

:

:

:

:

Advanced Posting Options

: If you check this box, email will be sent to you whenever someone replies to this message. Your email address must be entered above to receive notification. This notification will be cancelled automatically after 2 weeks.



 
Advanced Posting Tools
  Upload Photo  Select Gallery Photo  Attach Serial # List 
Return to Post 

TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Today's Featured Article - Tractor Profile: Allis-Chalmers Model G - by Staff. The first Allis-Chalmers Model G was produced in 1948 in Gasden, Alabama, and was designed for vegetable gardeners, small farms and landscape businesses. It is a small compact tractor that came with a complete line of implements especially tailored for its unique design. It featured a rear-mounted Continental N62 four-cylinder engine with a 2-3/8 x 3-1/2 inch bore and stroke. The rear-mounted engine provided traction for the rear wheels while at the same time gave the tractor operator a gre ... [Read Article]

Latest Ad: Oliver 550 Diesel runs like a watch three point hitch pto engine gone threw about two hundred hours ago nice clean tractor [More Ads]

Copyright © 1997-2024 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy