Welcome! Please use the navigational links to explore our website.
PartsASAP LogoCompany Logo (800) 853-2651

Shop Now

   Allis Chalmers Case Farmall IH Ford 8N,9N,2N Ford
   Ferguson John Deere Massey Ferguson Minn. Moline Oliver
 
Marketplace
Classified Ads
Photo Ads
Tractor Parts
Salvage

Community
Discussion Forums
Project Journals
Your Stories
Events Calendar
Hauling Schedule

Galleries
Tractor Photos
Implement Photos
Vintage Photos
Help Identify
Parts & Pieces
Stuck & Troubled
Vintage Ads
Community Album
Photo Ad Archives

Research & Info
Articles
Tractor Registry
Tip of the Day
Safety Cartoons
Tractor Values
Serial Numbers
Tune-Up Guide
Paint Codes
List Prices
Production Nbrs
Tune-Up Specs
Torque Values
3-Point Specs
Glossary

Miscellaneous
Tractor Games
Just For Kids
Virtual Show
Museum Guide
Memorial Page
Feedback Form

Yesterday's Tractors Facebook Page

  
Farmall & IHC Tractors Discussion Board

Re: 12volt battery in a 6 volt system


[ Expand ] [ View Follow Ups ] [ Post Followup ] [ Return to Forum ]

Posted by captaink on May 02, 2005 at 13:03:14 from (66.115.214.56):

In Reply to: 12volt battery in a 6 volt system posted by lekander883 on May 01, 2005 at 05:35:48:

Ah… I don’t want to offend anyone but here are a few things to consider when converting from 6-volts to 12-volt system ezpecialy the concern about burning out a 6-volt starter with 12-volts. I say this is a myth for the following reasons.

First, the law of physics states that in electricity; power in watts = amps multiplied by volts (or watts divided by volts = amps). Now, if you have a 600 amp 6 volt battery it will put out 3600 watts of power. If it takes all the electricity the 6-volt battery will put out to start an engine that means the starter takes 3600 watts of power. If you convert that system to 12-volts, 3600 watts divided by 12 volts equals 300 amps. Since the 6-volt starter is designed to carry 600 amps, the windings are heavy enough to handle the 300 amps at 12 volts easily. This equation is the same reason that when you wire in an electric motor or other similar load in your home or shop that takes 30 amps to run on 120 volts, it takes only 15 amps on 240 volts. Since on 240 volts it takes less amperage, lighter wire can be used to get the same wattage (power) for the motor.

Second, from the personal experience I have from converting a B, C, and an M to 12-volts. The M was done over 25 years ago. This tractor was (and still is) under a loader and was used almost daily for 18 years. In that time the only starter I replaced was the starter on the M and only once. Yup, you read that right ONCE. That replacement was the original one (1950 model) finally wearing the bushings far enough to cause the armature to drag on the fields. Nope, didn’t burn up, just wore out from all the starts it delivered.

I still maintain that if you burn out a 6-volt starter (either with a 6 or 12 volt battery) it is because you abused it by running it too long at one time and not giving it enough time to cool off.

By the way, I think the cost and effort of putting in a charging device is well worth it.


Follow Ups:




Post a Followup

:
:
: :

:

:

:

: If you check this box, email will be sent to you whenever someone replies to this message. Your email address must be entered above to receive notification. This notification will be cancelled automatically after 2 weeks.


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Today's Featured Article - Picking Corn - by Rick Nikolich. It was the day before Christmas shutdown at work and I asked our lead engineering expert Scott Andrzejewski what he was going to do over the holidays. He said that he had some corn that he still needed to pick with an antique one-row New Idea corn picker. Scott has a nice farm about an hour north of Lansing in St. Johns, MI. He wanted to get the rest of his corn in by the next day (Christmas Eve). We had about an inch of new snow on the ground and single digit temperatures. So in the bac ... [Read Article]

Latest Ad: Sell 1958 Hi-Altitude Massey Fergerson tractor, original condition. three point hitch pto engine, Runs well, photos available upon request [More Ads]

Copyright © 1997-2024 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.