What gauge wire to rewire 6volt Farmall H

Welcome Guest, Log in or Register
Author 
frankiee

08-27-2005 05:39:35




Report to Moderator

What gauge wire is good for a farmall H with 6 original 6 volt system. Right now it has steel multi strand wire. I want to replace it with copper wire of the correct wire gauge.




[Log in to Reply]   [No Email]
John T

08-27-2005 06:56:00




Report to Moderator
 Re: What gauge wire to rewire 6volt Farmall H in reply to frankiee, 08-27-2005 05:39:35  
Frankiee, I dont have any IHC diagrams or data, so can only tell you what I would use being a Nerdy engineer, part of which may be overkill but will work just fine.

While 14 and 16 Gauge wire will usually suffice and may be more like factory original, I use mostly No. 12 and No. 14 Gauge as follows:

CHARGING AND VOLTAGE SUPPLY AND LIGHTING CIRCUITS

I use 12 Gauge for the hot battery feed to the ammeters SUPPLY TERMINAL, which is often wired to the starter switch where the big battery cable is located, or direct to the hot ungrounded battery post itself.

I use 12 Gauge from the Ammeters other LOAD terminal down to the Voltage Regulator"s or Cutout Relay"s BAT terminal and 12 from the VR or cutout relays GEN (or ARM) terminal to the ARM post on the Generator.

For the Generators Field post n circuit up to the switch, 14 Gauge will suffice.

For the circuit to feed power to the lights, you can use 14 Gauge from the ammeters LOAD terminal over to the BAT input terminal on like light switches. If you only wanna buy one roll of wire, however, 12 would work just fine of course, even if its overkill. 14 Gauge will then work fine to feed the lights downstream of the switch.

IGNITION CIRCUIT

The ignition circuit (if a coil ignition) shouldnt be pulling much over 4 amps and 14 Gauge will do fine: HOWEVER, this is a circuit where youre only starting with 6 volts and should minimize voltage drop across the wires (even if miniscule) so as a pet peeve of mine I USE 12 GAUGE to feed the BAT input terminal on the ignition switch (from the ammeters LOAD terminal or wherever IHC fed it) and then 12 Gauge down to the coil and 12 Gauge from the coil to the distributor. NOTE: Its true at only 4 amps the voltage drop difference across a 12 or 14 Gauge wire at such short distance may be negligible, its just how I like to overkill on the ignition circuit and it sure cant hurt even if it dot help lol

If its a magneto with a kill switch, 14 gauge is sufficient from the mag to the switch

BATTERY CABLES

Since youre only starting with 6 volts and high current to the starter can drop voltage and waste heat energy across the cables,,,,, ,,I USE 00 GAUGE battery n starter n ground cables on all 6 volt tractors regardless

Sooooo ooooo oo 12 and 14 gauge will work fine even if its overkill, and all of it as 14 Gauge would likely work just as well (even like 16 Gauge in a lot of places), its just that I personally like 12 on the Ignition and Charging circuits and it drops less voltage (even if negligible differences) and sure cant hurt nuttin.

Im sure someone can furnish you an official IHC diagram (likely has a lot of 14 or 16 gauge even) and all Im saying is it cant hurt to oversize a lil bit, ESPECIALLY on those 00 Gauge battery n starter n ground cables !!!!! !

John T Nordhoff, retired electrical engineer in Indiana

[Log in to Reply]  [No Email]
txgrn

08-27-2005 06:39:29




Report to Moderator
 Re: What gauge wire to rewire 6volt Farmall H in reply to frankiee, 08-27-2005 05:39:35  
Without a lot of calculating, on that short of a run, 14 ga will easily handle 15 amps and 12 ga 20 amps.

Lights are about 35 watts so that's ~ 6 amps each; wiring the front two in series would be with 14 awg, generator output should be around 20 amps so it's 12 there, ignition runs like 5 amps so 14 is more than plenty for that.

Starting current is about 200 amps so your battery-starter loop should be at least size 00. Even if it's lower than that 00 won't hurt you and on cold days you'll be better off with it rather than lighter wire.

HTH

Mark

[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.