Author 
oleduke

08-30-2005 05:55:29




Report to Moderator

What is the proper reading for a amp. meter on a Super "H" with a generator charging system? Thanks to all who answer.




[Log in to Reply]   [No Email]
John T

08-30-2005 07:18:58




Report to Moderator
 Re: Amp meter in reply to oleduke, 08-30-2005 05:55:29  
Duke, it depends on a lot of variables, such as: Condition of Generator,,,,,Voltage Regulator (if it has one) settings,,,,,Condition of wiring and resistors and grounds on the light switch controllers (if it has that),,,,, ,,,,tightness and condition of belt,,,,, ,battery,,,,, ,,,and most important what the electrical loads are.

If it has a coil ignition thats around a 4 amp draw and lights on may be another 2 to 4 amps depending on type and number, so at slow idle, I would expect it may show a discharge. If all is in good condition I would expect it to charge at max rate maybe 10 to 15 amps right after start up (battery is down due to cranking) but then slowly decrease in the 2 to 5 amp range depending on some of the above.

At rated RPM if you dead ground the Generators Field post to the case that should allow for max charge rate but it still depends on the batterys state and condition of what she may register.

If she acts anywhere near that and the battery stays up despite long use and use of lights, I wouldnt worry too much about it, be sure the belt is tight.

John T

[Log in to Reply]  [No Email]
Janicholson

08-30-2005 06:24:10




Report to Moderator
 Re: Amp meter in reply to oleduke, 08-30-2005 05:55:29  
Assuming a good system (with regulator, ___not___ a three brush, or cutout relay with charge rate settings on the light knob), that the battery has been used to start the tractor, and that it is running at 1/2 throttle.

The amp meter should show about 12-15 amps charge for about 1-2 minutes then decrease from there to show 5 amp charge in 5 minutes or so. After about 15 min the charge should be about 2 amps (maybe 1 amp) and it should stay there till the engine is shut off. If the lights are turned on, the amp meter should spasm for a tenth of a second an the load is compensated for, and then settle back to the 1-2 amp charge rate. The amp meter only shows what is entering (charging), or leaving (discharging)the battery through all systems except the starter motor (which draws so much current that the meter would smoke if applied across it). The starter operates on a direct circuit (solenoid, or mechanical momentary contact heavy duty switch)
Not all systems will appear this way to the meeter viewer, if it charges more than five amps all the time into the good battery it needs to be checked with a volt meter. Charge volts for 6 volt systems (into an already charged battery lights off) shaould be 6.8-7.2 volts. A 12v. should show 13.8-14.3 volts. I'd adjust any regulkator out of those ranges.
Alternators are a different animal.
Hope this helps, Jim Nicholson

[Log in to Reply]  [No Email]
Bob M

08-30-2005 06:17:04




Report to Moderator
 Re: Amp meter in reply to oleduke, 08-30-2005 05:55:29  
With a good battery, the engine running at governed speed and the lights off, ammeter should indicate approx 15 amps charge immediately after startup. It should then taper to 5 amps or so as the battery comes back up (usually takes several minutes).

3 - 4 amps discharge at low idle is normal.



[Log in to Reply]  [No Email]
[Options]  [Printer Friendly]  [Posting Help]  [Return to Forum]   [Log in to Reply]

Hop to:


TRACTOR PARTS TRACTOR MANUALS
We sell tractor parts!  We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today. [ About Us ]

Home  |  Forums


Copyright © 1997-2023 Yesterday's Tractor Co.

All Rights Reserved. Reproduction of any part of this website, including design and content, without written permission is strictly prohibited. Trade Marks and Trade Names contained and used in this Website are those of others, and are used in this Website in a descriptive sense to refer to the products of others. Use of this Web site constitutes acceptance of our User Agreement and Privacy Policy

TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. None of these trademark holders are affiliated with Yesterday's Tractor Co., our products, or our website nor are we sponsored by them. John Deere and its logos are the registered trademarks of the John Deere Corporation. Agco, Agco Allis, White, Massey Ferguson and their logos are the registered trademarks of AGCO Corporation. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V.

Yesterday's Tractors - Antique Tractor Headquarters

Website Accessibility Policy