Re: HELP! Alternator conversion causes battery drain


[ View Follow Ups ] [ Post Followup ] [ Return to Tractor Talk ]

Posted by Jim G on April 19, 1998 at 19:35:54:

In Reply to: HELP! Alternator conversion causes battery drain posted by David on April 19, 1998 at 18:37:32:


: I recently converted my MF-65 from a generator/regulator setup to an alternator with an internal regulator (GM Delco). It charges very well but discharges the battery when turned off. Wiring is as follows:

: Terminal 1: Is connected to the BAT term. on the alternator.

: Terminal 2: Connected to IGN on ignition switch.

: BAT terminal: goes to the ammeter and ultimately to the pos. battery post.

: Have I wired incorrectly or do I need to add a diode or something. Thanks in advance for any information anyone may be able to provide.
: David

David, Sounds like it is wired correctly to me. Battery drain is sometimes caused by a bad diode in the rectifier bridge. Can you try a different alternator?