| Author |
[Modern View]
|
| ezed
09-20-2012 16:00:57
99.197.160.57
|
3-71 detroits, as used in a super 99, do not have air cut offs as do 4-53's in the 1900's and 2-53's in the 435 John Deere. I wonder why?? Has anyone found a simple way to install an air cut off on their 3-71? I was told that one off a 6-71 will fit however I am doubtful that oem air cleaner will line up. I worry about a stuck rack. ideas??? |
|
|
| larry duda
09-22-2012 18:47:54
208.94.74.65
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| You can modify your injector fuel rack . If an injector sticks the other 2 will return to idle.Larry |
|
|
| johns
09-21-2012 19:24:34
69.163.7.60
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| I have also been looking into doing this to my 99gm. One idea I"m looking into is some of my Oliver puller buddies have installed air shut-offs on their 1955 and 1850 pullers. Mills Fleet-Farm sells a guilotine that they use for less than $20. I"m wondering if a guy can install it between the blower and the intake that has GM stamped on it. That way the original air cleaners can be used. |
|
|
| ezed
09-22-2012 13:23:47
75.106.64.58
|
|
Re: Air Cut Off - Super 99 3-71 in reply to johns, 09-21-2012 19:24:34
|
|
| I see no reason why a cut off between the blower inlet and air cleaners would not work. What is the mills fleet farm cut off designed for??? What do they call it? Part number? I have been unable to find it on their web site |
|
|
| johncc
09-21-2012 15:04:19
24.140.42.228
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| we have 4- olivers with 371 d. nown have shutt offs. no place for them. if starts to run away shutt air off at air clearner. |
|
|
| 60 Fan
09-21-2012 08:55:47
208.126.138.2
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| [q :D uote="ezed"](reply to post at 16:00:57 09/20/12) [/quote]
Just another FYI, We had them on most older fire trucks with Detroit's. Older Pirsch, etc. Again as another reply has stated there was always the possibility of being in a combustible gas environment that could cause a runaway. Chances are you could find one of these in bigger salvage yards locally. |
|
|
| mm585
09-21-2012 08:00:18
166.182.3.169
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| I just restored a 1950 MFD it had one, It even had a decal on the dash that said emergency shut off. |
|
|
| duane o.
09-20-2012 20:38:51
68.149.231.9
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| positive air shutoffs were not a option on the tractors and were optional on all detroits from small to big. most shutoffs were used in oilfield areas of the country due to the gasses in the air around well sites.this is where to look if you were to find a used one. |
|
|
| gordey
09-20-2012 17:01:48
68.171.231.83
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| 3-71 olivers never came with one, if its a good running tractor its not likely to runaway, but a stuck rack is not uncommon if the tractors sat for a long time |
|
|
| OLarry from MD
09-20-2012 16:17:52
97.73.64.142
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:00:57
|
|
| The air cut off is supposed to be on there, i have seen them.On a 53 series it is a trip, on a 71 series it's a lever and cable to pull on and off. |
|
|
| ezed
09-20-2012 16:50:47
75.106.0.53
|
|
Re: Air Cut Off - Super 99 3-71 in reply to OLarry from MD, 09-20-2012 16:17:52
|
|
| I see no evidence of one ever being on this tractor. Likewise, of the dozen or so super 99's I have viewed none had an air cut off. Maybe it was an option. |
|
|
| OLarry from MD
09-21-2012 19:01:22
97.73.64.148
|
|
Re: Air Cut Off - Super 99 3-71 in reply to ezed, 09-20-2012 16:50:47
|
|
| Probably a replacement engine. |
|
|