Mark in Upstate
Member
All, previous posted about the Hydra -touch hydraulics on my 450 staying at high pressure after cycling, returning to center. I discussed with a dear friend and mechanic. He said I was very thorough. But this had him stumped. I pulled the relief valve apart again, removed the bypass screen that is unscrewed with a driver. I double checked all openings. The orifice on the screen was only .010 and Pete23. had noted that. 040 would work to bypass and relief the 'fulloffice pressure 'manifold issue. I opened it to. 060 because that is all I had. It solved the pressure issue. Thank you Pete23.
.040. will work very well when I replace the screen.
Mark
.040. will work very well when I replace the screen.
Mark