6 volt to 12 volt on model 140

I have done this conversion on a couple other tractors but not an International. I will put a condenser before the coil to drop the current from 12 to 6 volt. But what about the solenoid on the starter? Will it handle the 12 volts or do I need to add a resister there or do I replace it with a 12 volt solenoid?
 
Wayne - A purist would replace the old 6 volt solenoid with a 12 volt. In reality however existing 6 volt solenoid will do fine on 12 volts, so long as you don't overdo it (crank it too long) when starting the engine.

Incidentally it's a BALLAST RESISTOR - not a condenser - you will wire in series with the existing coil to reduce 12 volts to 6 volts.
 
Yes Bob you are right, it is a resister not a condenser. Wasn't thinking. I will suggest a change to a 12 volt solenoid but i'm doing this for my brother so it's up to him. Thanks for the info, Wayne
 

We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today.

Back