Excite switch for an altenator

Does anyone have the wiring diaghram for using a momentary switch such as a starter switch to excite a delco 12 SI alt.? Thanks!!!!
 
All it needs is 12V to one side of the switch and wire the other side to the #1 on the Alternator. It does not matter where the 12V comes from.
 
Run a wire from the ignition coil side of the ign switch, then to the excite switch (momentary contact push button) then to the #1 terminal of the alt. Start the tractor, and push the button, JimN
 
Probably the simplest is to run a wire from the alternator BAT post to one terminal of your momentary switch. Then run a 2nd wire from the other momentary switch terminal back to the alternator and connect it to the #1 aux terminal.
 
tennhillbilly: I have three as Bob describes, been working well since I installed them. One close to 20 years now, the other two 6 years. When the tractor fires up just hit the button and watch the amp gauge. When it hits positive you know it's charging.
 

We sell tractor parts! We have the parts you need to repair your tractor - the right parts. Our low prices and years of research make us your best choice when you need parts. Shop Online Today.

Back